<ErrorNumber>15376</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: Carrier required to do this proofing command
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_400/800_Proofing</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<OperatorAction>
<DescriptionText><text>
This error should not be seen under normal machine operation.  If you
see this error please call Creo service.
</text></DescriptionText>
</OperatorAction>
<ServiceInformation>
<DescriptionText><text>
If the cassette is installed properly you should be able to verify
that the sensor is working by using the "proof" command.  If the senor
is not working, check the TEE board, the sensor alignment and the cabling.
</text></DescriptionText>
</ServiceInformation>
<Cause>
The carrier was not detected at the start of the calibration
procedure.  The carrier is not installed properly or the sensors
are not working properly.
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../commands/proof_cal.xml</LinkAddress><LinkTitle>Command: proof cal</LinkTitle></Link>
<Link><LinkAddress>../commands/proof.xml</LinkAddress><LinkTitle>Command: proof</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:05 2008 PST
</Updated>
<Links>
</Links>
</Error>